Electric Drives Questions and Answers – Solid-State Switching Circuits – Current Source Inverter

This set of Electric Drives Multiple Choice Questions & Answers (MCQs) focuses on “Solid-State Switching Circuits – Current Source Inverter”.

1. The use of inductor in CSI is to make source current constant.
a) True
b) False
View Answer

Answer: a
Explanation: The inductor in CSI is used to make the source current constant. The input current of CSI should be constant.

2. The output voltage of CSI depends upon the load.
a) True
b) False
View Answer

Answer: a
Explanation: The output voltage of CSI depends upon the load. The output current of CSI is fixed as the input source current is fixed.

3. Which one of the element is used to make R load commutating?
a) Inductor
b) Capacitor
c) Resistor
d) Coil
View Answer

Answer: b
Explanation: Capacitor is used to make the R load commutating. It is used in parallel with the resistive load.

advertisement
advertisement

4. Calculate the minimum time period for ASCI using the data: R=12 kΩ, C=45 μF.
a) 2.58 sec
b) 2.16 sec
c) 2.23 sec
d) 2.48 sec
View Answer

Answer: b
Explanation: The minimum time period for ASCI is a 4×R×C = 4×12×45×.001 = 2.16 sec. The total time is the sum of charging and discharging time.

5. Full form of ASCI is ___________
a) Auto sequential commutated inverter
b) Auto starter commutated inverter
c) Auto sequential current inverter
d) Auto sequential current inserter
View Answer

Answer: a
Explanation: ASCI stands for Auto sequential commutated inverter. No external forced commutation is required for ASCI. The capacitor itself works as a load commutated inverter.
Sanfoundry Certification Contest of the Month is Live. 100+ Subjects. Participate Now!

6. Calculate the maximum frequency for ASCI using the data: R=15 kΩ, C=5 μF.
a) 3.51 Hz
b) 3.69 Hz
c) 3.33 Hz
d) 3.98 Hz
View Answer

Answer: c
Explanation: The maximum frequency for ASCI is a 1÷(4×R×C) = 1÷(4×15×5×.001) = 3.33 Hz. The total frequency is the sum of charging and discharging frequency.

7. The output current waveform for R load in CSI is ___________
a) Square
b) Triangular
c) Constant
d) Vertical
View Answer

Answer: a
Explanation: The output current of CSI for R load is square in nature. The amplitude of the output current varies from I to -I.
advertisement

8. T.H.D value for CSI is ________________
a) 48.43 %
b) 41.15 %
c) 39.15 %
d) 46.48 %
View Answer

Answer: a
Explanation: T.H.D value for VSI is 48.43 %. Triplen harmonics are present in CSI due to which harmonic content increases.

9. What is the distortion factor value in CSI?
a) .85
b) .90
c) .95
d) .88
View Answer

Answer: b
Explanation: The distortion value in CSI is .90. The r.m.s value of the fundamental current is 2√2I÷π and r.m.s value of the output current is I. The distortion factor is (2√2I÷π)÷I = .90.
advertisement

10. Number of switches turned on in CSI at a single time are __________
a) 2
b) 4
c) 5
d) 3
View Answer

Answer: a
Explanation: In CSI two switches conduct at a single time. The common switch used in CSI is thyristor. Thyristors are unidirectional, bipolar in nature.

11. Calculate the r.m.s value of the output current having an amplitude of 2 A for CSI.
a) 3 A
b) 4 A
c) 2 A
d) 1 A
View Answer

Answer: b
Explanation: The r.m.s value of the output current having an amplitude of 2 A for CSI is 2A. The waveform for output current is a square wave. The r.m.s value of the square wave is its amplitude.

12. Calculate the r.m.s value of the fundamental component of the output current having an amplitude of 3 A for CSI.
a) 2.80 A
b) 2.70 A
c) 2.54 A
d) 3.48 A
View Answer

Answer: b
Explanation: The r.m.s value of the fundamental component of the output current is 2√2I÷π=8.48÷3.14=2.70 A. The r.m.s value of the output current is I.

13. Calculate the string efficiency if the de-rating factor is .76.
a) 24 %
b) 25 %
c) 26 %
d) 27 %
View Answer

Answer: a
Explanation: The string efficiency is calculated for series and parallel connection of SCRs. The value of string efficiency is 1-(De-rating factor)=1-.76=24 %.

14. 20 V rated 8 SCRs are connected in series. The operation voltage of the string is 50. Calculate the De-rating factor.
a) .67
b) .68
c) .69
d) .70
View Answer

Answer: b
Explanation: The string efficiency can be calculated using the formula operation voltage÷(Number of SCRs×Rated voltage)=50÷(20×8)=.31. The De-rating factor value is 1-.31=.68.

15. Forced commutated CSI require _________
a) Diode
b) Resistor
c) Inductor
d) Capacitor
View Answer

Answer: d
Explanation: Forced commutated CSI requires a capacitor. The capacitor acts as a commutating element. It is connected in parallel with the load.

Sanfoundry Global Education & Learning Series – Electric Drives.

To practice all areas of Electric Drives, here is complete set of 1000+ Multiple Choice Questions and Answers.

If you find a mistake in question / option / answer, kindly take a screenshot and email to [email protected]

advertisement
advertisement
Subscribe to our Newsletters (Subject-wise). Participate in the Sanfoundry Certification contest to get free Certificate of Merit. Join our social networks below and stay updated with latest contests, videos, internships and jobs!

Youtube | Telegram | LinkedIn | Instagram | Facebook | Twitter | Pinterest
Manish Bhojasia - Founder & CTO at Sanfoundry
Manish Bhojasia, a technology veteran with 20+ years @ Cisco & Wipro, is Founder and CTO at Sanfoundry. He lives in Bangalore, and focuses on development of Linux Kernel, SAN Technologies, Advanced C, Data Structures & Alogrithms. Stay connected with him at LinkedIn.

Subscribe to his free Masterclasses at Youtube & discussions at Telegram SanfoundryClasses.