Control Systems Questions and Answers – Controller Components – II

This set of Control Systems Interview Questions and Answers for freshers focuses on “Controller Components – II”.

1. Different type of construction in permanent type DC magnet are :
a) Slotted armature type
b) Surface wound armature type
c) Surface wound rotating armature, stationary wound type.
d) All of the mentioned
View Answer

Answer: d
Explanation: Permanent magnet are the hard magnets that have broad B-H curve and can not be used as the core of the transformer due to their high retentivity and can be constructed by various ways such as slotted armature, surface wound type, surface wound rotating armature and stationary wound type.

2. Assertion (A): Slotted armature type in this armature is placed in slotted armature with DC windings placed inside the slots.
Reason (R): The construction is highly reliable and rugged but has high torque.
a) Both A and R are true and R is correct explanation of A
b) Both A and R are true but R is not correct explanation of A
c) A is true but R is false
d) A is false but R is true
View Answer

Answer: b
Explanation: Slotted armature as the name indicates in which armature is paced in slots but high inertia is present causing higher torque and less used.

3. A much lower inertia in Surface wound armature type is obtained by placing the winding on a non-magnetic cylinder which rotates in annular space between permanent magnet stator and stationary rotor.
a) True
b) False
View Answer

Answer: a
Explanation: Because of larger air gap strong permanent magnets are needed and much lower inertia is obtained by placing non-magnetic cylinder which rotates in annular space between permanent magnet stator and stationary rotor.
advertisement
advertisement

4. Lower inertia is obtained due to much larger gap and hence stronger magnets are used for this purpose.
a) True
b) False
View Answer

Answer: a
Explanation: Stronger permanent magnets are used so as to cause lower inertia as in Surface wound rotating armature and stationary wound type.

5. PMDC when coupled to a rotating shaft would generate a voltage proportional to speed and thus would serve as____________
a) Tachometer
b) Servomotor
c) D.C. motor
d) A.C. motor
View Answer

Answer: a
Explanation: Tachometer is a device that has relationship between voltage and speed and this is used in the controller to enhance the gain of the control system.
Note: Join free Sanfoundry classes at Telegram or Youtube

6. PMDC device is commonly employed for:
a) Speed feedback in speed control system
b) Internal velocity feedback loop of a position control system
c) This device is used in both speed feedback and internal velocity feedback control
d) None of the mentioned
View Answer

Answer: c
Explanation: The current rating of this type of device is very small and it is to be connected to the input end of the OP-AMP to get speed feedback and internal velocity feedback control.

7. Commutation process of a DC motor can be accomplished by solid devices (transistors and SCR’s).
a) True
b) False
View Answer

Answer: a
Explanation: Commutation process refers to the process in which the alternating current is used as input in the DC motor and in case of a DC motor this can be accomplished by solid devices such as the SCR’s and transistors.

advertisement

8. DC motors are constructed using Permanent Magnet resulting in:
a) Higher torque/inertia ratio
b) Higher operating frequency
c) No filed losses
d) All of the mentioned
View Answer

Answer: d
Explanation: DC motors are extensively using Permanent Magnets for its construction as they provide higher torque/inertia ratio, higher operating frequency, no field losses.

9. Speed of a permanent magnet DC motor:
a) It is directly proportional to the armature voltage at a given load torque
b) The speed torque characteristics are more flat than in a wound field motor
c) It depends upon armature voltage and are more flat than in a wound field motor
d) None of the mentioned
View Answer

Answer: c
Explanation: Speed of a permanent magnet DC motor is directly proportional to the armature voltage at a given load torque and speed torque characteristics are more flat than in a wound field motor as the effect of armature reaction is less pronounced in a PM motor.
advertisement

10. Assertion (A): DC servomotors have practically taken over from AC servomotors in most control application.
Reason (R): Low brush commutator friction and still higher torque/inertia have been achieved in DC servomotors.
a) Both A and R are true and R is correct explanation of A
b) Both A and R are true but R is not correct explanation of A
c) A is true but R is false
d) A is false but R is true
View Answer

Answer: a
Explanation: AC servomotors are replaced by DC servomotors as frictional losses and higher torque/inertia ratios have been achieved.

Sanfoundry Global Education & Learning Series – Control Systems.
To practice all areas of Control Systems for Interviews, here is complete set of 1000+ Multiple Choice Questions and Answers.

If you find a mistake in question / option / answer, kindly take a screenshot and email to [email protected]

advertisement
advertisement
Subscribe to our Newsletters (Subject-wise). Participate in the Sanfoundry Certification contest to get free Certificate of Merit. Join our social networks below and stay updated with latest contests, videos, internships and jobs!

Youtube | Telegram | LinkedIn | Instagram | Facebook | Twitter | Pinterest
Manish Bhojasia - Founder & CTO at Sanfoundry
Manish Bhojasia, a technology veteran with 20+ years @ Cisco & Wipro, is Founder and CTO at Sanfoundry. He lives in Bangalore, and focuses on development of Linux Kernel, SAN Technologies, Advanced C, Data Structures & Alogrithms. Stay connected with him at LinkedIn.

Subscribe to his free Masterclasses at Youtube & discussions at Telegram SanfoundryClasses.