Analytical Instrumentation Questions and Answers – Instrumentation for Electr…

This set of Analytical Instrumentation Multiple Choice Questions & Answers (MCQs) focuses on “Instrumentation for Electron Spectroscopy”.

1. A basic X-ray source includes which of the following components?
a) Large target anode
b) Large target cathode
c) Small target anode
d) Small target cathode
View Answer

Answer: a
Explanation: A basic X-ray source includes a large target anode. It also has a heating element.

2. The anode is held at __________ positive potential and the filament is held at ____________ potential.
a) High, ground
b) Ground, high
c) Low, high
d) High, low
View Answer

Answer: a
Explanation: The anode is held at high potential and the filament is held at ground potential. Electrons are accelerated from the filament.

3. Which of the following is one of the most commonly used anode material?
a) Carbon
b) Tungsten
c) Magnesium
d) Cesium
View Answer

Answer: c
Explanation: Magnesium is one of the most commonly used anode material. Aluminium is also commonly used.
advertisement
advertisement

4. Which is the most intense line in the X-ray spectrum?
a) Kα1
b) Kα2
c) Kα12
d) Kα22
View Answer

Answer: c
Explanation: Kα12 is the most intense line in the X-ray spectrum. Different lines have specific energies.

5. Which of the following must be used with the X-ray source to have high energy resolution?
a) Chopper
b) Vacuum chamber
c) Accelerator
d) Monochromator
View Answer

Answer: d
Explanation: Monochromator must be used with the X-ray source to have high energy resolution. It will also remove the satellite lines.
Sanfoundry Certification Contest of the Month is Live. 100+ Subjects. Participate Now!

6. Magnetic deflection energy analysers are effective than electrostatic types.
a) True
b) False
View Answer

Answer: a
Explanation: Magnetic deflection energy analysers are effective than electrostatic types. It is less convenient to design and use.

7. Double-pass cylindrical mirror energy analyser has how many mirrors?
a) One
b) Two
c) Three
d) Four
View Answer

Answer: b
Explanation: Double-pass cylindrical mirror energy analyser has two mirrors. It is commonly used in electron spectroscopy.
advertisement

8. In spherical sector analyser, __________ is detected and plotted as a function of energy.
a) Mass
b) Charge
c) Number of electrons striking the detector
d) Mass to charge ratio
View Answer

Answer: c
Explanation: In spherical sector analyser, the number of electrons striking the detector is detected and plotted as a function of energy. It is detected for a constant potential.

9. Which of the following is the most commonly used detector in ESCA and AES?
a) Electron multiplier
b) Dynodes
c) Photovoltaic cell
d) Photomultiplier
View Answer

Answer: a
Explanation: Electron multiplier is the most commonly used detectors in ESCA and AES. It is similar to photomultiplier.
advertisement

10. Electron detector has a _______ doped glass tube with a secondary semiconducting coating.
a) Quartz
b) Silica
c) Lead
d) Cesium
View Answer

Answer: c
Explanation: Electron detector has a lead doped glass tube with a secondary semiconducting coating. It has a high secondary electron shield.

11. The output of the multiplier is fed to which of the following immediately?
a) Pulse amplifier discriminator
b) DAC
c) ADC
d) Multichannel analyser
View Answer

Answer: a
Explanation: The output of the multiplier is fed to pulse amplifier discriminator. It is then fed to a multichannel analyser.

12. Which of the following is the ideal vacuum for electron spectrometers?
a) 10-6 torr
b) 10-7 torr
c) 10-8 torr
d) 10-9 torr
View Answer

Answer: a
Explanation: 10-6 torr is the ideal vacuum for electron spectrometers. Vacuum below 10-6 torr can also be used.

13. Which of the following is the most commonly used magnetic shielding?
a) Helmholtz coils
b) Ferro-magnetic shielding
c) Faraday shield
d) Magnetometer probe
View Answer

Answer: b
Explanation: Ferro-magnetic shielding is the most commonly used magnetic shielding. Helmholtz coil can be used as alternative.

14. Charging effect can be suppressed by supplying flood of electrons having which of the following?
a) Uniform low energy
b) Uniform low mass
c) Uniform high energy
d) Uniform high mass
View Answer

Answer: a
Explanation: Charging effect can be suppressed by supplying flood of electrons having uniform low energy. It also results in attainment of additional useful information.

15. Synchroton radiation has several advantages over conventional radiation.
a) True
b) False
View Answer

Answer: a
Explanation: Synchroton radiation has several advantages over conventional radiation. The resolution is very high.

Sanfoundry Global Education & Learning Series – Analytical Instrumentation.

To practice all areas of Analytical Instrumentation, here is complete set of 1000+ Multiple Choice Questions and Answers.

advertisement
advertisement
Subscribe to our Newsletters (Subject-wise). Participate in the Sanfoundry Certification contest to get free Certificate of Merit. Join our social networks below and stay updated with latest contests, videos, internships and jobs!

Youtube | Telegram | LinkedIn | Instagram | Facebook | Twitter | Pinterest
Manish Bhojasia - Founder & CTO at Sanfoundry
Manish Bhojasia, a technology veteran with 20+ years @ Cisco & Wipro, is Founder and CTO at Sanfoundry. He lives in Bangalore, and focuses on development of Linux Kernel, SAN Technologies, Advanced C, Data Structures & Alogrithms. Stay connected with him at LinkedIn.

Subscribe to his free Masterclasses at Youtube & discussions at Telegram SanfoundryClasses.