Analytical Instrumentation Questions and Answers – Instrumentation of X-Ray Spectroscopy

This set of Analytical Instrumentation Multiple Choice Questions & Answers (MCQs) focuses on “Instrumentation of X-Ray Spectroscopy”.

1. In X-ray spectrometers, the specimen or the sample is placed after which of the following components?
a) X-ray tube
b) Monochromator
c) Collimator
d) Detector
View Answer

Answer: a
Explanation: In X-ray spectrometers, the specimen or the sample is placed after the X-ray tube. The X-ray tube is the source of the X-ray.

2. Which of the following components are used to generate X-rays?
a) Meyer tube
b) West tube
c) Anger tube
d) Coolidge tube
View Answer

Answer: d
Explanation: Coolidge tube is used to generate X-rays. It the source of X-rays. Coolidge tube requires stabilised current and high voltage.

3. Using which of the following components is the generated x-rays focussed upon the specimen?
a) X-ray tube
b) Monochromator
c) Collimator
d) Detector
View Answer

Answer: c
Explanation: Collimator is used to focus the generated x-rays upon the specimen. The collimator is in between the specimen under analysis and the Coolidge tube.
advertisement
advertisement

4. The cathode in the Coolidge tube is made of which of the following elements?
a) Quartz
b) Iron
c) Tungsten
d) Barium
View Answer

Answer: c
Explanation: The cathode in the Coolidge tube is made of tungsten. The anode is made of copper.

5. The cathode in the Coolidge tube is kept in an inclined manner.
a) True
b) False
View Answer

Answer: b
Explanation: The anode in the Coolidge tube is kept in an inclined manner. The anode is made of copper.
Sanfoundry Certification Contest of the Month is Live. 100+ Subjects. Participate Now!

6. Which of the following is not a target metal used in the Coolidge tube?
a) Rhodium
b) Cobalt
c) Gold
d) Silver
View Answer

Answer: c
Explanation: Gold is not used as a target metal in the Coolidge tube. The other target metals are copper, molybdenum and chromium.

7. How can the resolution of the collimator be increased?
a) By reducing the separation between the metal plates of the collimator
b) By increasing the separation between the metal plates of the collimator
c) By increasing the number of metal plates
d) By decreasing the number of metal plates
View Answer

Answer: a
Explanation: The resolution of the collimator can be increased by reducing the separation between the metal plates of the collimator. Collimator has a series of closely spaced parallel metal plates.
advertisement

8. When x-rays emitted from molybdenum are allowed to pass through a zirconium filter, which of the following occurs?
a) It absorbs radiation of shorter wavelength
b) It absorbs radiation of longer wavelength
c) It allows radiation of shorter wavelength to pass through
d) It allows radiation in a particular band to pass through
View Answer

Answer: b
Explanation: When x-rays emitted from molybdenum are allowed to pass through a zirconium filter, it absorbs radiation of shorter wavelength. It allows radiation of a stronger wavelength to pass through.

9. When compared to filters, monochromators provide much signal to noise ratio.
a) True
b) False
View Answer

Answer: a
Explanation: When compared to filters, monochromators provide much signal to noise ratio. Monochromators are used for removal of unwanted wavelengths.
advertisement

10. Which of the following crystals are not suited for x-ray grating?
a) Topaz
b) Lithium fluoride
c) Calcium fluoride
d) Sodium fluoride
View Answer

Answer: d
Explanation: The crystal which is not suited for x-ray grating is sodium fluoride. Other crystals which are suitable for x-ray grating are gypsum and sodium chloride.

11. Given below is the block diagram of X-ray spectrometer. Identify the unmarked component.
The unmarked component is specimen of X-ray spectrometer
a) Filter
b) Monochromator
c) Specimen
d) Amplifier
View Answer

Answer: c
Explanation: The unmarked component is specimen. It is the sample under analysis.

12. The x-rays generated come out of the Coolidge tube through which of the following?
a) Beryllium window
b) Tungsten window
c) Collimator
d) Target material
View Answer

Answer: a
Explanation: The x-rays generated come out of the Coolidge tube through a beryllium window. Some energy is lost as heat.

Sanfoundry Global Education & Learning Series – Analytical Instrumentation.

To practice all areas of Analytical Instrumentation, here is complete set of 1000+ Multiple Choice Questions and Answers.

If you find a mistake in question / option / answer, kindly take a screenshot and email to [email protected]

advertisement
advertisement
Subscribe to our Newsletters (Subject-wise). Participate in the Sanfoundry Certification contest to get free Certificate of Merit. Join our social networks below and stay updated with latest contests, videos, internships and jobs!

Youtube | Telegram | LinkedIn | Instagram | Facebook | Twitter | Pinterest
Manish Bhojasia - Founder & CTO at Sanfoundry
Manish Bhojasia, a technology veteran with 20+ years @ Cisco & Wipro, is Founder and CTO at Sanfoundry. He lives in Bangalore, and focuses on development of Linux Kernel, SAN Technologies, Advanced C, Data Structures & Alogrithms. Stay connected with him at LinkedIn.

Subscribe to his free Masterclasses at Youtube & discussions at Telegram SanfoundryClasses.