Analytical Instrumentation Questions and Answers – Column Efficiency and Column Resolution

This set of Analytical Instrumentation Questions and Answers for Freshers focuses on “Column Efficiency and Column Resolution”.

1. Which of the following is the distance that the solute moves while undergoing one partition?
a) Retention distance
b) Distribution constant
c) Plate height
d) Column packing length
View Answer

Answer: c
Explanation: Plate height is the distance that the solute moves while undergoing one partition. It is expressed in length.

2. Which of the following conditions will cause the efficiency of the column to increase?
a) Plate number becomes greater, plate height becomes smaller
b) Plate number becomes smaller, plate height becomes smaller
c) Plate number becomes greater, plate height becomes larger
d) Plate number becomes greater, plate height becomes larger
View Answer

Answer: a
Explanation: The efficiency of the column increases when the plate number becomes greater and the plate height becomes smaller. Column efficiency greatly depends on plate height and plate number.

3. Which of the following is the expression for Eddy diffusion in the column, if ‘γ’ represents obstruction factor, ‘dp’ represents particle diameter, ‘DM’ represents Solute diffusion co-efficient and ‘λ’ represents function for packing uniformity?
a) λ dM
b) 2 γ DM
c) DM γ
d) λ/dM
View Answer

Answer: a
Explanation: Eddy diffusion is given as, A = λ dp. It is also called multipath term.
advertisement
advertisement

4. Which of the following is the expression for longitudinal diffusion in the column, if ‘γ’ represents obstruction factor, ‘dM’ represents particle diameter, ‘DM’ represents Solute diffusion co-efficient and ‘λ’ represents function for packing uniformity?
a) λ dM
b) 2 γ DM
c) DM γ
d) λ/dM
View Answer

Answer: b
Explanation: Longitudinal diffusion is given as, B = 2 γ DM.It is also called axial diffusion.

5. In gas-liquid chromatography, when films are used in the interior of the capillary column, then what is the value of Eddy diffusion?
a) Greater than 1
b) Less than 1
c) Zero
d) Less than zero
View Answer

Answer: c
Explanation: In gas-liquid chromatography, when films are used in the interior of the capillary column the value of Eddy diffusion (A) is zero. To minimize A, diameter of packing should be small and uniform.
Sanfoundry Certification Contest of the Month is Live. 100+ Subjects. Participate Now!

6. For an unpacked coated capillary column, the obstruction factor takes which of the following values?
a) 0
b) 0.6
c) 1
d) 1.6
View Answer

Answer: c
Explanation: For an unpacked coated capillary column, the value of the obstruction factor is 1. For a packed column, the value is 0.6.

7. Base line resolution is achieved when degree of resolution/separation is ______
a) 1
b) 0
c) 0.5
d) 1.5
View Answer

Answer: d
Explanation: Base line resolution is achieved when degree of resolution/separation is 1.5. The baseline bandwidths of adjacent bands are almost constant.
advertisement

8. Which of the following equations give the expression for plate number, N when ‘tR’ is the adjusted retention time and ‘Wb’ is the width at the base of the peak which is equal to 4 standard deviations.
a) 16 tR2/Wb
b) 4 tR2/Wb
c) (4tR/Wb)2
d) 4 (tR/Wb)2
View Answer

Answer: c
Explanation: The expression for plate number, N is given as N = (4tR/Wb)2. It is a dimensionless quantity.

9. It is more difficult to measure the width at half peak height than the base width in the detector output.
a) True
b) False
View Answer

Answer: b
Explanation: The width at half peak height is easier to measure than the base width. Hence, the plate number is calculated at peak height.
advertisement

10. The solute, while moving in the column is always in equilibrium with both the stationary phase and the mobile phase.
a) True
b) False
View Answer

Answer: a
Explanation: The solute, while moving in the column is always in equilibrium with both the stationary phase and the mobile phase. But, the two phases will never be in equilibrium with each other.

Sanfoundry Global Education & Learning Series – Analytical Instrumentation.

To practice all areas of Analytical Instrumentation for Freshers, here is complete set of 1000+ Multiple Choice Questions and Answers.

If you find a mistake in question / option / answer, kindly take a screenshot and email to [email protected]

advertisement
advertisement
Subscribe to our Newsletters (Subject-wise). Participate in the Sanfoundry Certification contest to get free Certificate of Merit. Join our social networks below and stay updated with latest contests, videos, internships and jobs!

Youtube | Telegram | LinkedIn | Instagram | Facebook | Twitter | Pinterest
Manish Bhojasia - Founder & CTO at Sanfoundry
Manish Bhojasia, a technology veteran with 20+ years @ Cisco & Wipro, is Founder and CTO at Sanfoundry. He lives in Bangalore, and focuses on development of Linux Kernel, SAN Technologies, Advanced C, Data Structures & Alogrithms. Stay connected with him at LinkedIn.

Subscribe to his free Masterclasses at Youtube & discussions at Telegram SanfoundryClasses.